🔆 Illuminate Your Safety with Precision!
The Solarmeter Model 8.0 UVC Lamp Meter is a handheld digital UV light meter designed for testing UVC light bulbs, ensuring they meet performance standards. It features a measurement range of 0-1999 μW/cm2 UVC, is powered by a long-lasting 9-volt battery, and boasts NIST traceable accuracy, making it an essential tool for effective disinfection and safety.
E**T
Works exactly as advertised.
Got mine today and tested it with a number of UV-C Sterilization Wands, LEDs, Lamps and some protective eye wear.This Meter registered zero (000) when it should have, and accurately measured UV-C levels from various UV-CLEDs, and from small to large UV-C Lamps including a 36 Watt UV-C Tube which exceeded the maximum readingat several inches distance.At this price, I'd like memory and graphing over time functions, but no one else is doing this well at this price point at this time, so they get my vote and my purchase.
A**R
Ok
Ok
N**H
good product
Easy to use
B**N
great meter, great price.
Can show any UV-C emission from standard fluorescents (shouldn't be any), and measure the emission of UV-C sterilization lamps (aging, efficiency, etc).
D**B
Five Stars
good functional meter
M**E
UVC meter comes with NIST certificate
July 11, 2017This device, made by Solar Light Company, Inc., is the Solarmeter Model 8.0 UVC meter. You know how you think of light as being in the UVA and UVB ranges (where “UV” means Ultra Violet”). Those ranges of light, whose frequency is so high that they are barely invisible to the naked eye, are generated by the sun as well as other sources of light.UVC rays generated by the sun struggle then give up and die before getting through Earth’s atmosphere (which is why we need the ozone layer of Earth to stop shrinking), but they are emitted by sources here on Earth such as germicidal lamps (on purpose) and welding torches (not on purpose). UVC rays are just as invisible as and arguably more dangerous or more useful than UVA and UVB rays, which means that under certain circumstances those UVC rays should be measured. The product under review does just that.It blocks UVA and UVB rays and measures UVC rays from 0 to 1999 microwatts per square centimeter. You aim it at the source, push a button, and the display at the top of the front of the rectangular box shows how many µw were detected in that square centimeter. If the display shows 17 then everything is probably OK, but if it’s 1,830 and it’s supposed to be only 1,200 then you might have a problem that needs fixing. FWIW, it measures at approximately 254 nanometers.The accuracy of the product under review is what’s called “NIST-traceable,” which means each particular device has been tested according to the standards of the National Institute of Standards and Technology, which is regarded as the universal keeper of such defined knowns as how long a meter is, and a piece of paper attesting to the results is included in each box. Presumably the manufacturer doesn’t sell any devices that fail.I use this product mainly to test my friends’ and family members’ ability to detect and measure UVC rays. First, on a clear day at noon I have them stare into the sun for a couple minutes, then look at a welding torch for a couple more minutes. Second, I ask them how many microwatts they think the welding torch gave off per centimeter squared, which answer I’ve already measured using the Solarmeter Model 8.0 UVC Meter - Measures 254 +/-8nm with range from 0-1999 µW/cm² UVC. Most of them are way off and blind, so don’t try this at home.You can test whether a particular lamp is giving off enough UVC power to kill certain germs, you can test whether a particular lens of a pair of eclipse glasses is really doing its job blocking UVC, and you can test whether it’s safe from the standpoint of UVC rays for a Schrodinger cat to spend 2 hours 7 minutes tanning on an equatorial beach on Venus (Answer: No, the limit appears to 2 hours 6 minutes).For the reasons above I award all five stars.
E**O
Show false positive reading of 2, and has narrow spectrum
As shown in the included picture, this constantly has a false positive reading of 2 even when it's indoors and in its case. And yes, I did try wiping the sensor too which didn't change anything. As such, I find the device to be grossly untrustworthy. This false reading is true during the daytime and at night as well.Secondly, this measures a very narrow band of the UVC spectrum. The UVC spectrum is 100-280nm but this meter measures only 246-262nm. There are other UVC meters sold on Amazon that measure a wider range.Needless to say, I will be returning this item.
R**X
Highly specific. Excellent for sterilization lamp qualification.
I purchased three different brand sterilization lamps and a sterilization personal wand. Only the wand registered on the meter. This meter will show you are using the correct wavelength to sterilize a surface. A narrow bandwidth of specification, is the only way to be sure you are not pay for a harmless wavelength of UV light to do a life or death qualified task.... that brand of wand was Mobile Klean.Stay safe.